Finding the perfect boiler for your house can be a daunting task especially considering the fact that there are many good brands available on the market. Worcester is one of those brands and if you are thinking of purchasing a boiler from this brand you definitely need to know some of the problems it experiences so that you can be in a better position to resolve them in the future. Below we are going to focus on the Worcester 24i boiler problems.
Table of Contents
What Is A Worcester 24i Boiler?
The Worcester 24i formally known as the Worcester Bosch Greenstar 24i boiler is a condensing gas boiler. This boiler comes with a Condensesure Siphon, a feature that can prevent the condensate pipe from freezing over. The Worcester 24i boiler is designed to use less energy and it is compatible with Greenskies photovoltaic panels which means you can use the panels to supplement the boilers hot water output.
Worcester 24i Boiler Problems
NB: The Worcester 24i boiler is sold without any malfunctioning parts and the problems indicated below are usually influenced by wear and tear or human error.
1. Condensate Pipe Blocked
One of the most common problems experienced by a Worcester 24i boiler is that the condensate pipe may get blocked. This problem usually happens in winter when the pipe is exposed to the elements. When a Worcester 24i boiler experiences this problem it usually displays an EA229 error code.
Troubleshooting Condensate Pipe Blocked Problem
When the condensate pipe of your Worcester 24i boiler gets blocked you should check for any obstruction on the pipe. If it is ice that is blocking your pipe you need to thaw the pipe by pouring hot water on top of the pipe. In order to prevent this problem from happening again you should put the pipe in a warm place like your house or alternatively you can insulate the condensate pipe using lagging.
2. Worcester Boiler Does Not Produce Hot Water
Another problem which you may encounter with a Worcester 24i boiler is that it may fail to produce hot water. This problem usually happens when the diverter valve is faulty or when the PCB unit is damaged.
Troubleshooting Worcester Boiler Does Not Produce Hot Water Problem
When your Worcester 24i boiler is failing to produce hot water you should call a qualified technician to fix the diverter valve or PCB unit. These are the components that are mainly responsible for the availability of hot water in the boiler.
3. Worcester Boiler Leaks
The Worcester 24i boiler also experiences problems of leaking. When it has this problem it usually displays an error code of EA338 or A281. Leakages in a Worcester 24i boiler are usually caused by blown out pump seals or a corroded heat exchanger.
Troubleshooting Worcester Boiler Leaks Problem
When your Worcester boiler has a problems of leaking you should start by checking for leakages on the boiler. When you identify them you can use a sealent to cover them up. However, if this fails it may be best to contact a qualified technician to help you resolve the problem.
4. Worcester Boiler Does Not Receive Power
The Worcester 24i boiler may sometimes fail to receive power. This problem usually happens when you do not plug in the boiler correctly into the mains power supply or when the PCB is faulty. A tripped RCD can also cause this problem.
Troubleshooting Worcester Boiler Does Not Receive Power Problem
When your Worcester 24i boiler is not receiving power the first thing you should do is to check whether your boiler is connected properly. The next thing you should do is to check the PCB and if it is faulty you will need to replace it with a new one. If the RCD is tripped you should fix it.
5. Boiler Makes Noise
Another problem which you may experience with the Worcester 24i boiler is that the boiler may start making unusual noises. This problem happens when limescale builds up on the heat exchanger or when there is an airlock in the central heating system.
Troubleshooting Boiler Makes Noise Problem
When your Worcester 24i boiler is making noises you should start by calling a qualified technician to take care of the problem for you. In order to avoid this problem in the future you should install a limescale inhibitor to your boiler in order to reduce the buildup of limescale.
6. Boiler Overheats
The Worcester 24i boiler can sometimes overheat. When this happens the boiler usually displays error codes like E5218, E5332, E9219 and E9224. This problem is usually caused by a faulty central heating pump, a blocked condensate pipe and a blocked PRV.
Troubleshooting Boiler Overheats Problem
When your Worcester 24i boiler starts overheating you should call a qualified technician to look at the problem. They will be in a better position to fix the problem for you.
7. Boiler Loses Pressure
The Worcester 24i boiler can sometimes lose pressure. This problem is caused by a leak in the boiler system either from the radiator or rad valve.
Troubleshooting Boiler Loses Pressure Problem
When your Worcester 24i boiler starts losing pressure you need to check the central heating system and ensure that there are no leakages. You should also consider calling in a qualified technician to help you resolve the problem.
Why Is My Worcester Boiler Not Firing For Heating?
Your Worcester boiler may not be firing for boiling because there is no power supply or the boiler is not connected properly.
What To Do If My Worcester Boiler Is Not Working?
If your Worcester Boiler is not working you should start by checking the boiler to ensure that everything is working. If you notice any problems you should consider hiring a qualified technician to resolve the problem for you.
Conclusion
The problems indicated in this article can easily be resolved so you do not need to worry if you are thinking of purchasing this boiler. The Worcester 24i boiler is durable and reliable and just like any other boiler on the market it has its own problems as shown above.